Laser handpiece and applicator refurbishment

We diagnose, repair and refurbish laser handpieces and applicators. We tailor the work to the equipment's design and condition to restore correct operation. Servicing in Wrocław for customers throughout Poland.

from EUR 220

Free diagnostics when you commission repair or refurbishment

Engineer travel and transport are charged separately.

When should a handpiece be checked?

Symptoms are not a final diagnosis. A similar problem can have different causes, so the handpiece and its interaction with the device need technical inspection before parts are selected.

The handpiece has stopped cooling

The cause may involve coolant circulation, heat dissipation, power or controls. We check the Peltier module only in designs that use one.

Laser performance has decreased

Reduced performance may involve the optics, laser diode module or power supply. Treatment results alone are insufficient to assess laser output.

The handpiece overheats

We check the cooling system and thermal connections. We do not assume that replacing thermal paste will be sufficient.

Coolant is leaking

Inspection identifies the leak location and the condition of hoses, connections and seals. Report a leak before using the equipment further.

Damaged seals

Worn or incorrectly seated O-rings and seals may cause leaks. We select parts compatible with the design.

Unstable diode operation

Irregular operation requires checks of the module, its power supply and connections. The symptom does not automatically mean the diode needs replacing.

Contaminated cooling channels

Deposits and contamination may restrict flow. Cleaning scope depends on channel design and access.

What does refurbishment include?

Not every handpiece contains all the components described. We determine the specific repair scope after diagnostics and agree it with the customer.

Laser diode replacement

We diagnose the faulty laser diode module and select a compatible replacement. Replacement feasibility and component cost depend on the model.

Cooling element replacement

We diagnose and replace faulty thermoelectric cooling modules (Peltier/TEC) where used in the handpiece.

Thermal paste replacement

We clean contact surfaces and restore thermal contact between cooling system components according to their design.

Seal and component replacement

We replace damaged O-rings, seals, connections and other faulty parts identified during diagnostics.

Cleaning and sealing

We remove contamination and clean internal components. Suitable silicone sealants are used only where permitted by the manufacturer's design.

How does the repair proceed?

  1. Report a fault

    Provide the model, symptoms and circumstances in which the problem appeared. We will agree equipment handover or a visit.

  2. Handpiece diagnostics

    We check the handpiece and, where needed, its interaction with the device.

  3. Identifying faulty components

    We establish the cause and availability of suitable parts.

  4. Agreeing the quotation

    We agree costs and scope before starting the repair.

  5. Repair or refurbishment

    We carry out the agreed work and replace the identified components.

  6. Post-repair checks

    We check for leaks, cooling and operation within the scope appropriate to the design.

  7. Equipment handover

    We explain the work completed and return the equipment as agreed.

Refurbishment costs and terms

Handpiece refurbishment

from EUR 220

Free diagnostics when you commission repair or refurbishment

EUR 0

Travel and transport

Engineer travel and transport are charged separately.

The final price depends on the fault, required components and scope. The starting price of EUR 220 does not mean replacement of all parts. Individual repairs, including diode replacement, may cost more; parts are quoted individually.

Diagnostics only: scope and terms. See prices for individual jobs.

Why Laser Tech Service?

Diagnosis before replacing parts

We trace symptoms to their cause to select the necessary work rather than replacing parts on assumptions.

Compatible components

We consider the handpiece design and its systems' requirements when selecting parts.

Cooling system assessment

We examine the relationship between heat removal, the thermal interface and cooling circuit.

Post-repair checks

We check the repaired systems before returning the equipment.

Handpiece repair examples

Laser power supply and electronics repair — repair terms from EUR 165.

Module replacement after liquid ingress — Poznań

Module replacement after liquid ingress — Poznań

Symptom: A damaged laser diode module following liquid ingress.

Cause: An incorrectly seated seal caused a loss of watertightness and liquid ingress into the module.

Result: The module and seal were replaced, restoring the assembly's seal.

Full case study →
Diode laser handpiece service — Poznań

Diode laser handpiece service — Poznań

Symptom: A leaking handpiece with contamination inside.

Cause: Loss of housing integrity allowed dust to enter, including the optical area.

Result: The interior and optics were cleaned and the handpiece was resealed.

Full case study →
ESTETECH cooling repair — Poznań

ESTETECH cooling repair — Poznań

Symptom: The handpiece surface was not cooling correctly.

Cause: Diagnostics identified a faulty Peltier module.

Result: The module was replaced, the thermal interface renewed and restored cooling checked.

Full case study →

Handpiece refurbishment questions

Prices start at EUR 220. The final quotation depends on the fault, parts and scope. This is not a price for replacing every component.

Yes, if the handpiece design and availability of a compatible module allow the repair. We confirm feasibility and cost after diagnostics.

The problem may involve coolant circulation, heat dissipation, power or controls. In some designs, a Peltier module or poor thermal contact is responsible; diagnostics establish this.

Repair feasibility depends on the leak location and component condition. After inspection, we select seals or other components and check for leaks after repair.

Yes, when you commission repair or refurbishment from Laser Tech Service. If you order diagnostics only, the terms for that service apply.

Yes. Travel and transport are charged separately, including when diagnostics are free with a repair order.

In many cases, faulty parts can be replaced. Repair feasibility and justification depend on handpiece condition, design and parts availability; we do not promise to repair every model.

Diagnostic findings, the extent of damage, compatible parts availability and required checks. Timing is agreed after assessing the specific equipment.

Arrange handpiece servicing