Diode laser diagnostics

We identify faults in laser devices and handpieces so that aesthetic clinic, salon and laser hair removal studio owners can make informed repair decisions. Wrocław and throughout Poland.

from EUR 165

Free diagnostics when you commission a repair

Engineer travel is charged separately, including when you commission a repair.

What do diagnostics include?

Laser equipment diagnostics

We assess the device in relation to the reported problem, taking its design and the conditions in which the fault occurs into account.

Laser handpiece diagnostics

We check the handpiece and how it operates with the device. The scope depends on the model and symptoms.

Identifying the cause of the fault

We locate the source of the problem and distinguish symptoms from causes. We do not assume that the laser diode module needs replacing.

Recommendations and proposed repair

We provide a verbal explanation, a written technical conclusion, recommendations and a proposed repair.

When does a diode laser need diagnostics?

Similar symptoms can have different causes. The cause can only be established by examining the specific device. We tailor the work to the model and problem; not every diagnostic assessment requires the same measurements, dismantling or calibration.

The laser will not switch on

The problem may involve the incoming power supply, connections, power supply unit or control system. A device that does not respond does not necessarily have a damaged laser module.

Handpiece not cooling

The cause may involve coolant circulation, heat dissipation, power or cooling control. In models with thermoelectric cooling, the Peltier module may also be relevant.

The laser has lost output

Reduced performance may relate to contaminated optics, the laser diode module, the power supply or a protection system limiting operation. Observing treatment results does not replace a technical assessment. Read more →

The device overheats

Restricted airflow, a dirty heat exchanger, a faulty fan or coolant circulation problems may impair heat dissipation. Operating conditions must also be considered. Read more →

Error messages appear on the display

A message may relate to temperature, flow, communication or other protective functions; the meaning of a code depends on the model. Please provide the exact code and when it appears.

No laser pulse

Possible causes include the device not being ready, an active safety interlock, a trigger signal problem, a handpiece connection or the power supply. This does not automatically mean the diode needs replacing.

How do diagnostics work?

  1. Report the fault

    Tell us the symptoms, your town or city and the model, if known. Describe the circumstances in which the problem appeared.

  2. Agree the arrangements

    We confirm the scope, diagnostic cost and service arrangements. Travel and its cost are agreed separately.

  3. Inspect the device and handpiece

    We carry out a technical assessment appropriate to the device design and reported symptoms.

  4. Explanation and written conclusion

    You receive a verbal explanation of the findings, a written technical conclusion, recommendations and a proposed repair.

  5. Your repair decision

    There is no obligation to proceed with a repair. If you commission Laser Tech Service to repair the device, diagnostics are free. Travel remains a separate charge.

Diagnostic costs

Diagnostics without a repair order

from EUR 165

Diagnostics with a repair order

EUR 0

Engineer travel

Charged separately

We do not charge for diagnostics when you commission Laser Tech Service to carry out the repair. This is not a refund, discount or EUR 165 deduction from the repair price. Transport is not included.

See diagnostic and travel charges in the price list →

Examples from our work

These documented cases show why symptoms must be traced to their cause. The fan replacement example concerns a laser device whose technology has not been confirmed, rather than a confirmed diode laser.

Laser handpiece and applicator refurbishment — repair scope and terms from EUR 220.

Laser power supply and electronics repair — repair terms from EUR 165.

Module replacement after liquid ingress — Poznań

Module replacement after liquid ingress — Poznań

Symptom: A damaged laser diode module following liquid ingress.

Cause: An incorrectly seated seal caused a loss of watertightness and liquid ingress into the module.

Result: The module and seal were replaced, restoring the assembly's seal.

Full case study →
Diode laser handpiece service — Poznań

Diode laser handpiece service — Poznań

Symptom: A leaking handpiece with contamination inside.

Cause: Loss of housing integrity allowed dust to enter, including the optical area.

Result: The interior and optics were cleaned and the handpiece was resealed.

Full case study →
Cooling fan replacement — Wrocław

Cooling fan replacement — Wrocław

Symptom: Insufficient cooling of a laser device.

Cause: Faulty fans and substantial dust inside the device.

Result: The fans were replaced, dust removed and restored cooling operation checked.

Full case study →

Diagnostic questions

Diagnostics without a repair order start at EUR 165. This includes the device and handpiece, fault localisation, recommendations and a proposed repair. Travel costs are agreed separately.

Yes. If you commission Laser Tech Service to repair the device, diagnostics are free. This is not a refund or discount. Travel is charged separately.

No. Transport is not included in the price from EUR 165 and does not become free when you commission a repair. Its cost is agreed before the visit.

Handpiece diagnostics are part of the service. If the problem only concerns the handpiece, describe it when contacting us. Whether we can check it without the device, and on what terms, is agreed individually according to the model and symptoms.

You will receive a verbal explanation of the findings, a written technical conclusion, recommendations and a proposed solution to the identified fault.

No. You decide after reviewing the findings and proposal. Without a repair order, diagnostics start at EUR 165; with a repair commissioned from Laser Tech Service, they are free. Travel is charged separately in both cases.

Book diagnostics

Engineer travel is charged separately, including when you commission a repair. +48 790 402 597 · contact@lasertechservice.pl